3RB1246-1QB01-0AA0

ELEKTRON. UEBERLASTRELAIS MIT INTEGRIERTER THERMISTOR- UND ERDSCHLUSSUEBERWACHUNG 1S/1OE (UEBERLAST/THERMISTOR) 1S/1OE (ERDSCHLUSS) 6,3 BIS 25 A DC 24V BISTABILE AUSGAENGE

3RB1246-1QB10

DISCONTINUED PRODUCT OVERLOAD RELAY 6.3…25 A FOR FULL MOTOR PROTECTION SIZE S00/S0, CLASS 5…30 INDIVID. MOUNT. MAIN CIRCUIT: ST TRANSFORMER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE RESET STANDARD FUNCTIONS MONOSTABLE OUTPUTS OVERLOAD WARNING DC 24 V

3RB1246-1QB11

DISCONTINUED PRODUCT OVERLOAD RELAY 6.3…25 A FOR FULL MOTOR PROTECTION SIZE S00/S0, CLASS 5…30 INDIVID. MOUNT. MAIN CIRCUIT: ST TRANSFORMER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE RESET STANDARD FUNCTIONS BISTABLE OUTPUTS OVERLOAD WARNING DC 24 V

3RB1246-1QB20

DISCONTINUED PRODUCT OVERLOAD RELAY 6.3…25 A FOR FULL MOTOR PROTECTION SIZE S00/S0, CLASS 5…30 INDIVID. MOUNT. MAIN CIRCUIT: ST TRANSFORMER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE RESET INT. GROUND FAULT DETECTION MONOSTABLE OUTPUTS GROUND FAULT SIGNALING DC 24 V

3RB1246-1QB21

SOLID-STATE OVERLOAD RELAY WITH INTEGRATED THERMISTOR PROTECTION, 6.3 TO 25 A DC 24V WITH INTERNAL EARTH-FAULT DETECTION 1NO/1NC (OVERLOAD/THERMISTOR) 1NO/1NC (EARTH FAULT) BISTABLE OUTPUTS

3RB1246-1QB30

DISCONTINUED PRODUCT OVERLOAD RELAY 6.3…25 A FOR FULL MOTOR PROTECTION SIZE S00/S0, CLASS 5…30 INDIVID. MOUNT. MAIN CIRCUIT: ST TRANSFORMER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE RESET INT. GROUND FAULT DETECTION MONOSTABLE OUTPUTS OVERLOAD WARNING DC 24 V

3RB1246-1QB31

SOLID-STATE OVERLOAD RELAY WITH INTEGRATED THERMISTOR PROTECTION, 6.3 TO 25 A DC 24V WITH INTERNAL EARTH-FAULT DETECTION 1NO/1NC (OVERLOAD/THERMISTOR/ EARTH-FAULT) 1NO/1NC (OVERLOAD WARNING) BISTABLE OUTPUTS

3RB1246-1QB40

DISCONTINUED TYPE OVERLOAD RELAY 6.3 TO 25 A FOR FULL MOTOR PROTECTION SZ S00/S0, CLASS 5 TO 30 INDIVIDUAL MOUNTING MAIN CIRC.: STRAIGHT-THROUGH CONVERTER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE-RESET WITH ANALOG OUTPUT MONOSTABLE OUTPUTS GROUND FAULT SIGNAL DC 24 V

3RB1246-1QG00

DISCONTINUED PRODUCT OVERLOAD RELAY 6.3…25 A FOR FULL MOTOR PROTECTION SIZE S00/S0, CLASS 5…30 INDIVID. MOUNT. MAIN CIRCUIT: ST TRANSFORMER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE RESET STANDARD FUNCTIONS MONOSTABLE OUTPUTS GROUND FAULT SIGNALING AC 110…120 V, 50/60 HZ

3RB1246-1QG00-0AA0

ELEKTRON. UEBERLASTRELAIS MIT INTEGRIERTER THERMISTOR- UND ERDSCHLUSSUEBERWACHUNG 1S/1OE (UEBERLAST/THERMISTOR) 1S/1OE (ERDSCHLUSS) 6,3 BIS 25 A AC 110 BIS 120V 50/60HZ MONOSTABILE AUSGAENGE

3RB1246-1QG00-0FM0

SOLID-STATE OVERLOAD RELAY, W. INTEGR. THERMISTOR PROTECT. 6.3…25 A AC 110…120 V 50/60 HZ GROUND FAULT MONIT. THROUGH CONNECTION OF EXTERNAL SUMMATION CURRENT TRANSF. 1NO/1NC (OVERC./THERMISTOR) 1NO/1NC (GROUND FAULT), MONOST. KLOECKNER-MOELLER, ZWA25 (OVERCURRENT/THERMISTOR) 1NO/1NC (GROUND FAULT), MONOSTABLE KLOECKNER-MOELLER, ZWA25

3RB1246-1QG01

DISCONTINUED PRODUCT OVERLOAD RELAY 6.3…25 A FOR FULL MOTOR PROTECTION SIZE S00/S0, CLASS 5…30 INDIVID. MOUNT. MAIN CIRCUIT: ST TRANSFORMER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE RESET STANDARD FUNCTIONS BISTABLE OUTPUTS GROUND FAULT SIGNALING AC 110…120 V, 50/60 HZ

3RB1246-1QG01-0AA0

ELEKTRON. UEBERLASTRELAIS MIT INTEGRIERTER THERMISTOR- UND ERDSCHLUSSUEBERWACHUNG 1S/1OE (UEBERLAST/THERMISTOR) 1S/1OE (ERDSCHLUSS) 6,3 BIS 25 A AC 110 BIS 120V 50/60HZ BISTABILE AUSGAENGE

3RB1246-1QG10

DISCONTINUED PRODUCT OVERLOAD RELAY 6.3…25 A FOR FULL MOTOR PROTECTION SIZE S00/S0, CLASS 5…30 INDIVID. MOUNT. MAIN CIRCUIT: ST TRANSFORMER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE RESET STANDARD FUNCTIONS MONOSTABLE OUTPUTS OVERLOAD WARNING AC 110…120 V, 50/60 HZ

3RB1246-1QG11

DISCONTINUED PRODUCT OVERLOAD RELAY 6.3…25 A FOR FULL MOTOR PROTECTION SIZE S00/S0, CLASS 5…30 INDIVID. MOUNT. MAIN CIRCUIT: ST TRANSFORMER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE RESET STANDARD FUNCTIONS BISTABLE OUTPUTS OVERLOAD WARNING AC 110…120 V, 50/60 HZ

3RB1246-1QG20

OVERLOAD RELAY 6.3…25 A FOR FULL MOTOR PROTECTION SIZE S00/S0, CLASS 5…30 STAND-ALONE INST. MAIN CIRCUIT: STRAIGHT- THROUGH TRANSF. AUX. CIRCUIT: SCREW CONN. MANUAL-AUTOMATIC-REMOTE-RESET INT. GROUND FAULT DETECTION MONOST. OUTPUTS GROUND FAULT SIGNALING AC 110…120 V, 50/60 HZ

3RB1246-1QG21

SOLID-STATE OVERLOAD RELAY WITH INTEGRATED THERMISTOR PROTECTION, 6.3 TO 25 A AC 110 TO 120V 50/60HZ WITH INTERNAL EARTH-FAULT DETECTION 1NO/1NC (OVERLOAD/THERMISTOR) 1NO/1NC (EARTH FAULT) BISTABLE OUTPUTS

3RB1246-1QG30

DISCONTINUED PRODUCT OVERLOAD RELAY 6.3…25 A FOR FULL MOTOR PROTECTION SIZE S00/S0, CLASS 5…30 INDIVID. MOUNT. MAIN CIRCUIT: ST TRANSFORMER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE RESET INT. GROUND FAULT DETECTION MONOSTABLE OUTPUTS OVERLOAD WARNING AC 110…120 V, 50/60 HZ

3RB1246-1QG31

SOLID-STATE OVERLOAD RELAY WITH INTEGRATED THERMISTOR PROTECTION, 6.3 TO 25 A AC 110 TO 120V 50/60HZ WITH INTERNAL EARTH-FAULT DETECTION 1NO/1NC (OVERLOAD/THERMISTOR/ EARTH-FAULT) 1NO/1NC (OVERLOAD WARNING) BISTABLE OUTPUTS

3RB1246-1QG40

DISCONTINUED TYPE OVERLOAD RELAY 6.3 TO 25 A FOR FULL MOTOR PROTECTION SZ S00/S0, CLASS 5 TO 30 INDIVIDUAL MOUNTING MAIN CIRC.: STRAIGHT-THROUGH CONVERTER AUX. CIRCUIT: SCREW TERMINAL MANUAL-AUTOMATIC-REMOTE-RESET WITH ANALOG OUTPUT MONOSTABLE OUTPUTS GROUND FAULT SIGNAL AC 110…120 V, 50/60 HZ