Siemens Spare Parts
« Previous 1 … 3 4 5 6 7 … 179 Next »
1LE1001-1DB23-4AB0
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160M * 11KW (50HZ) 60HZ: IEC 60034-30 12.6KW, EPACT 15HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 3, IM B6, IM B7, IM B8, IM V5 W/O CANOPY, IM V6, MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP NO MOUNTING AT NDE POSSIBLE
1LE1001-1DB23-4AB0-ZB07
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160M * 11KW (50HZ) 60HZ: IEC 60034-30 12.6KW, EPACT 15HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B3, IM B6, IM B7, IM B8, IM V5 W/O CANOPY, IM V6, MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP NO MOUNTING AT NDE POSSIBLE B07=EXTRA NAME PLATE VOLTAGE TOLERANCE
1LE1001-1DB23-4AB0-ZB20
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160M * 11KW (50HZ) 60HZ: IEC 60034-30 12.6KW, EPACT 15HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B3, IM B6, IM B7, IM B8, IM V5 W/O CANOPY, IM V6, MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP NO MOUNTING AT NDE POSSIBLE B20=STANDARDLINE
1LE1001-1DB23-4FB0
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160M * 11KW (50HZ) 60HZ: IEC 60034-30 12.6KW, EPACT 15HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 5, IM V1 W/O CANOPY, IM V3, FLANGE: FF300 MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP NO MOUNTING AT NDE POSSIBLE
1LE1001-1DB23-4FB0-ZB07
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160M * 11KW (50HZ) 60HZ: IEC 60034-30 12.6KW, EPACT 15HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B5, IM V1 W/O CANOPY, IM V3, FLANGE: FF300 MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP NO MOUNTING AT NDE POSSIBLE B07=EXTRA NAME PLATE VOLTAGE TOLERANCE
1LE1001-1DB23-4FB0-ZB20
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160M * 11KW (50HZ) 60HZ: IEC 60034-30 12.6KW, EPACT 15HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B5, IM V1 W/O CANOPY, IM V3, FLANGE: FF300 MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP NO MOUNTING AT NDE POSSIBLE B20=STANDARDLINE
1LE1001-1DB43-4AB0
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160L * 15KW (50HZ) 60HZ: IEC 60034-30 17.3KW, EPACT 20HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 3, IM B6, IM B7, IM B8, IM V5 W/O CANOPY, IM V6, MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP, NO MOUNTING AT NDE POSSIBLE
1LE1001-1DB43-4AB0-ZB07
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160L * 15KW (50HZ) 60HZ: IEC 60034-30 17.3KW, EPACT 20HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 3,IM B6,IM B7,IM B8,IM V5 W/O CANOPY, IM V6, MOTOR PROT., W. 3 PTC THERMIST. FOR SHUTDOWN TERMINAL BOX AT TOP, NO MOUNTING AT NDE POSSIBLE B07=EXTRA NAME PLATE VOLTAGE TOLERANCE VOLTAGE TOLERANCE
1LE1001-1DB43-4AB0-ZB20
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160L * 15KW (50HZ) 60HZ: IEC 60034-30 17.3KW, EPACT 20HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B3, IM B6, IM B7, IM B8 IM V5 W/O CANOPY, IM V6, MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP NO MOUNTING AT NDE POSSIBLE B20=STANDARDLINE
1LE1001-1DB43-4FB0
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160L * 15KW (50HZ) 60HZ: IEC 60034-30 17.3KW, EPACT 20HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 5, IM V1 W/O CANOPY, IM V3, FLANGE: FF300 MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP, NO MOUNTING AT NDE POSSIBLE
1LE1001-1DB43-4FB0-ZB07
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160L * 15KW (50HZ) 60HZ: IEC 60034-30 17.3KW, EPACT 20HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B5, IM V1 W/O CANOPY, IM V3, FLANGE: FF300 MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP, NO MOUNTING AT NDE POSSIBLE B07=EXTRA NAME PLATE VOLTAGE TOLERANCE
1LE1001-1DB43-4FB0-ZB20
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, GENERAL LINE HIGH EFFICIENCY IE2, 4POLE * FS160L * 15KW (50HZ) 60HZ: IEC 60034-30 17.3KW, EPACT 20HP 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B5, IM V1 W/O CANOPY, IM V3, FLANGE: FF300 MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP, NO MOUNTING AT NDE POSSIBLE B20=STANDARDLINE
1LE1001-1DB7.-….
LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING, INCR. OUTPUT HIGH EFFICIENCY, 4POLE * FS160L * 22KW (50HZ)
We deliver worldwide and at any time including customs clearance.
In advance, we also are gladly available during an individual phone consultation.
Payment
on invoice
Worldwide
Shipping
Offers within
12 hours
Fast
delivery