3DY2024

INSULATED COUPLER 12KV 80/125/160KA/ 2500/3000A

3DY2041

INSULATED COUPLER 24KV 50KA/630A

3DY2042

INSULATED COUPLER 24KV 80KA/ 1250-2500A

3DY2061

INSULATED COUPLER 36KV 50KA/630A

3DY2062

INSULATED COUPLER 36KV 80KA/1250A

3DY2063

INSULATED COUPLER 36KV 80KA/ 2500/3000A

3EB2003-7D

SURGE ARRESTER 3EB2 POLYMERIC HOUSING FOR RAIL PROTECTION, APPLIED STANDARD: EN50526-1 FIRETEST ACCORDING EN45545-2 CONT. OPERATING VOLTAGE 300V DC FIXED INSTALLATION NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 0.72KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 3KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 133MM HEIGHT 200MM SHORT TERM LOAD SSL 160N

3EB2010-7D

SURGE ARRESTER 3EB2 POLYMERIC HOUSING FOR RAILWAY APPLICATION 600-800V DC APPLIED STANDARD: EN50526-1 FIRETEST ACCORDING EN45545-2 CONT. OPERATING VOLTAGE 1KV DC FIXED INSTALLATION NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 2.4KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 10KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 133MM HEIGHT 200MM SHORT TERM LOAD SSL 160N

3EB2020-7D

SURGE ARRESTER 3EB2 POLYMERIC HOUSING FOR RAILWAY APPLICATION 1500V DC APPLIED STANDARD: EN50526-1 FIRETEST ACCORDING EN45545-2 CONT. OPERATING VOLTAGE 2KV DC FIXED INSTALLATION NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 4.8KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 20KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 133MM HEIGHT 200MM SHORT TERM LOAD SSL 160N

3EC1010

SURGE ARRESTER 1 KV 10KA

3EC2030

SURGE ARRESTER FOR DC VOLTAGE 4.0KV, 10KA

3EC3010

SURGE ARRESTER 3EC3 PORCELAIN HOUSING FOR RAILWAY APPLICATION 600-800V DC APPLIED STANDARD: EN50526-1 CONT. OPERATING VOLTAGE 1KV DC UP TO 160KM/H NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 2.4KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 10KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 165MM HEIGHT 223MM SHORT TERM LOAD SSL 600N HOLE CIRCLE DIAMETER 162MM, 3 HOLES DIAMETER 11MM

3EC3020

SURGE ARRESTER 3EC3 PORCELAIN HOUSING FOR RAILWAY APPLICATION 1500V DC APPLIED STANDARD: EN50526-1 CONT. OPERATING VOLTAGE 2KV DC UP TO 160KM/H NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 4.8KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 20KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 165MM HEIGHT 223MM SHORT TERM LOAD SSL 600N HOLE CIRCLE DIAMETER 162MM, 3 HOLES DIAMETER 11MM

3EC3040

SURGE ARRESTER 3EC3 PORCELAIN HOUSING FOR RAILWAY APPLICATION 3000V DC APPLIED STANDARD: EN50526-1 CONT. OPERATING VOLTAGE 4KV DC UP TO 160KM/H NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 9.6KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 40KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 165MM HEIGHT 223MM SHORT TERM LOAD SSL 600N HOLE CIRCLE DIAMETER 162MM, 3 HOLES DIAMETER 11MM

3EE1380-1.E1

SPECIAL-PURPOSE SURGE ARRESTER EXTINCTION VOLTAGE 38KV, SHORT- CIRCUIT CURRENT STRENGTH 300KA

3EE2220-2.A0

SPECIAL-PURPOSE SURGE ARRESTER RATED VOLTAGE 22KV, ENERGY ABSORPT.CAPACITY 10KJ/KV SHORT-CIRCUIT CURRENT STRENGTH 50KA

3EF1150-0A

SURGE LIMITER RATED VOLTAGE 15KV

3EF3036-0

SURGE LIMITER INDOOR VERSION RATED VOLTAGE 3.6KV

3EF3048-0

SURGE LIMITER INDOOR VERSION RATED VOLTAGE 4.8KV

3EF4014

SURGE ARRESTER FOR PROTECTION OF CONVERTER FOR DRIVES RATED VOLTAGE 1.4KV