Siemens Spare Parts
« Previous 1 … 4,789 4,790 4,791 4,792 4,793 … 30,420 Next »
3EB2003-7D
SURGE ARRESTER 3EB2 POLYMERIC HOUSING FOR RAIL PROTECTION, APPLIED STANDARD: EN50526-1 FIRETEST ACCORDING EN45545-2 CONT. OPERATING VOLTAGE 300V DC FIXED INSTALLATION NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 0.72KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 3KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 133MM HEIGHT 200MM SHORT TERM LOAD SSL 160N
3EB2010-7D
SURGE ARRESTER 3EB2 POLYMERIC HOUSING FOR RAILWAY APPLICATION 600-800V DC APPLIED STANDARD: EN50526-1 FIRETEST ACCORDING EN45545-2 CONT. OPERATING VOLTAGE 1KV DC FIXED INSTALLATION NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 2.4KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 10KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 133MM HEIGHT 200MM SHORT TERM LOAD SSL 160N
3EB2020-7D
SURGE ARRESTER 3EB2 POLYMERIC HOUSING FOR RAILWAY APPLICATION 1500V DC APPLIED STANDARD: EN50526-1 FIRETEST ACCORDING EN45545-2 CONT. OPERATING VOLTAGE 2KV DC FIXED INSTALLATION NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 4.8KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 20KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 133MM HEIGHT 200MM SHORT TERM LOAD SSL 160N
3EC3010
SURGE ARRESTER 3EC3 PORCELAIN HOUSING FOR RAILWAY APPLICATION 600-800V DC APPLIED STANDARD: EN50526-1 CONT. OPERATING VOLTAGE 1KV DC UP TO 160KM/H NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 2.4KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 10KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 165MM HEIGHT 223MM SHORT TERM LOAD SSL 600N HOLE CIRCLE DIAMETER 162MM, 3 HOLES DIAMETER 11MM
3EC3020
SURGE ARRESTER 3EC3 PORCELAIN HOUSING FOR RAILWAY APPLICATION 1500V DC APPLIED STANDARD: EN50526-1 CONT. OPERATING VOLTAGE 2KV DC UP TO 160KM/H NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 4.8KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 20KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 165MM HEIGHT 223MM SHORT TERM LOAD SSL 600N HOLE CIRCLE DIAMETER 162MM, 3 HOLES DIAMETER 11MM
3EC3040
SURGE ARRESTER 3EC3 PORCELAIN HOUSING FOR RAILWAY APPLICATION 3000V DC APPLIED STANDARD: EN50526-1 CONT. OPERATING VOLTAGE 4KV DC UP TO 160KM/H NOMINAL DISCHARGE CURRENT 20KA ARRESTER DESIGNATION: DC-B URES (10KA, 8/20) = 9.6KV CHARGE TRANSFER RATING 2.5C RATED THERMAL ENERGY 40KJ SHORT-CIRCUIT CURRENT 40KA CREEPAGE DISTANCE 165MM HEIGHT 223MM SHORT TERM LOAD SSL 600N HOLE CIRCLE DIAMETER 162MM, 3 HOLES DIAMETER 11MM
3EE1380-1.E1
SPECIAL-PURPOSE SURGE ARRESTER EXTINCTION VOLTAGE 38KV, SHORT- CIRCUIT CURRENT STRENGTH 300KA
3EE2220-2.A0
SPECIAL-PURPOSE SURGE ARRESTER RATED VOLTAGE 22KV, ENERGY ABSORPT.CAPACITY 10KJ/KV SHORT-CIRCUIT CURRENT STRENGTH 50KA
3EF4014
SURGE ARRESTER FOR PROTECTION OF CONVERTER FOR DRIVES RATED VOLTAGE 1.4KV