Siemens Spare Parts
« Previous 1 … 4,749 4,750 4,751 4,752 4,753 … 30,420 Next »
3AJ9058-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 20KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH IN CONNECTION COMPARTMENT AND ON BUSBAR WITH MOTOR OPERATING MECHANISM AC 230V
3AJ9066-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 20KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM WITHOUT EARTHING SWITCH IN CONNECTION COMPARTMENT, EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM AC 100V
3AJ9067-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 20KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM WITHOUT EARTHING SWITCH IN CONNECTION COMPARTMENT, EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM AC 110V
3AJ9068-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 20KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM WITHOUT EARTHING SWITCH IN CONNECTION COMPARTMENT, EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM AC 230V
3AJ9076-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 20KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM AC 100V
3AJ9077-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 20KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM AC 110V
3AJ9078-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 20KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM AC 230V
3AJ9321-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM DC 24V, INCL. VARISTOR CIRCUITRY
3AJ9322-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM DC 48V, INCL. VARISTOR CIRCUITRY
3AJ9323-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM DC 60V, INCL. VARISTOR CIRCUITRY
3AJ9324-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM DC 110V, INCL. VARISTOR CIRCUITRY
3AJ9325-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM DC 220V, INCL. VARISTOR CIRCUITRY
3AJ9326-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AC 100V
3AJ9327-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AC 110V
3AJ9328-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AC 230V
3AJ9331-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM DC 24V, INCL. VARISTOR CIRCUITRY
3AJ9332-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM DC 48V, INCL. VARISTOR CIRCUITRY
3AJ9333-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM DC 60V INCL. VARISTOR CIRCUITRY
3AJ9334-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM DC 110V, INCL. VARISTOR CIRCUITRY
3AJ9335-…..-0…
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM DC 220V, INCL. VARISTOR CIRCUITRY
We deliver worldwide and at any time including customs clearance.
In advance, we also are gladly available during an individual phone consultation.
Payment
on invoice
Worldwide
Shipping
Offers within
12 hours
Fast
delivery